Sandro Dual

  • The Most Advanced Technology, Hybrid system
  • 755nm Alexandrite & 1064nm Nd: YAG
Irradiation Type
Alexandrite & Nd:YAG Hybrid Mode
Pulse energy
50J (Alexandrite), 80J (Nd:YAG), 60J (Hybrid mode)
Pulse duration
0.2 to 300ms, 5 to 50ms (Hybrid)
Repetition Rate
0.5 to 10Hz, Up to 2Hz (Hybrid)
Spot size
2,3,5,7,10,12,15,18, 20mm / Attachable cartridges
Cooling system
SCS gas (Skin Cooling Spray)
Air Cooling connector(Option)
Electrical requirements
220/230V, 50/60Hz, 8kVA(Hybrid)
Dimension
470(W)x900(D)x1100(H) mm
Weight
110kg

WHAT IS SANDRO-DUAL?

  • Sandro Dual combines 755nm Long-PulsedAlexandrite and 1064nm Nd:YAG Lasers into one system that provides a wide range of pulse durations, higher repetition rates, and various spot sizes.
  • Its Hybrid Mode is a cutting-edge technology, capable of sequentially emitting two wavelengths (either 755nm-1064nm or 1064nm-755nm) at a preset time interval, providing optimal results for hair removal and vascular lesion treatments to all skin types, even with a lower fluency.
  • Sandro Dual has some of the highest repetition rates, up to 10Hz and 2Hz in Hybrid mode. This not only shortens procedural time, but increases therapeutic efficacy for hair removal, resulting in fast ROI and higher patient satisfaction.

MAIN FEATURES & INDICATIONS

Safe Treatments

-Flat-Top Beam Profile

-Preset Parameters

-Adjustable Pre and Post Cooling System

Smart Handpiece

-Ergonomic Handpiece

-Automatic sensor for measuring the skin’s surface temperature

-Sophisticated, easy-to-handle design

Hybrid System

-High Performance of Sequential Irradiation

-Superior Safety and Efficacy for All Skin Types

Fast Treatments

-Up to 10Hz Available

-Up to 2Hz at Hybrid Mode

-Up to 20mm Spot Size

Hair Removal – Underarm, Arm, Leg, Back, Bikini, Philtrum, Beard. 

Pigmented Lesions – Freckles, Solar Lentigines, Seborrheic Keratosis Moles, Warts

Vascular Lesions – Facial Veins, Rosacea, Diffused Redness, Leg Veins

Skin Rejuvenation – Enlarged Pores, Fine Lines, Wrinkles, Uneven Skin Texture

ENHANCED HAIR REMOVAL WITH SANDRO DUAL

Sandro Dual is the ideal solution for hair removal with the largest spot of 20mm and the highest    repetition of SHz.

Enhanced 5Hz at 755nm and 2Hz at Hybrid mode shorten the procedure time by 30-50%, comparable to the conventional laser with1.5Hz at the same spot size.

Now, you can experience high-speed hair removal with better efficacy


Thinking in Action with SANDRO DUA

SANDRO DUAL is the ideal solution for hair removal with the largest spot of 25 mm and the highest repetition of 10 Hz.

Enhanced 10 Hz at 755 nm & 1064 nm and 2 Hz at Hybrid mode shorten the procedure time by 30-50%, comparable to the conventional laser with 10 Hz at the larger spot size.

Now, you can experience high-speed hair removal with better efficacy.


Specifications & Main Features

Sandro Dual
Wavelength755nm, 1064nm
Laser TypeLong Pulsed Alexandrite /Nd:YAG/ Hybrid
Pulse EnergyMax. 50J (Alexandrite) Max. 80J (Nd:YAG) Max. 60J (Hybrid)
Pulse Width0.2~300ms / 5~50ms (Hybrid)
Pulse Rate0.5~10Hz / 2Hz(Hybrid)
Spot Size2,3,5,7,10,12,15,18,20mm
Cooling TypeSCS (Skin Cooling Spray)
Dimensions1100(H) * 470(W) * 900(D)
Weight110Kg

Fast Treatment

•Up to 5Hz at 755nm

•Up to 2Hz at Hybrid mode

•Up to 20mm spot size

Hybrid System

•For All Skin Types

•More Safety and Better Efficacy

Smart Handpiece

•Light Weight

•Temperature Auto-sensing

•SCS (Skin Cooling Spray)

Hair Removal

LesionWavelength  (nm)Spot Size  (mm)Pulse  Duration (ms)Fluence  (J/cm2)Frequency  (Hz)
PrePost
Fine Hair7551031524.4(4.4)
7551531224.4(4.4)
7552031124.4(4.4)
10641053024.4(4.4)
Normal Hair7551051524.4(4.4)
7551551324.4(4.4)
7552051124.4(4.4)
10641015254.4(4.4)
Thick Hair75510101524.4(4.4)
75515101324.4(4.4)
75520101124.4(4.4)
106410302024.4(4.4)
Hybrid  Normal Hair7551531024.4(4.4)
1064310
106415101524.4(4.4)
755105
Trichostasis  spinulosa75512314-2024.4(4.4)
•Fine Hair : female philtrum, arm, … •Normal Hair : female armpit, legs, male back, … •Thick Hair : bikini, beard, …

Pigmented Lesions

Pigmented Lesion Treatment
LesionWavelength  (nm)Spot Size  (mm)Pulse  Duration  (ms)Fluence  (J/cm2)Frequency  (Hz)SCS
PrePost
Freckles7552-30.2401Off4.4
75530.3301Off4.4
Solar Lentigines  Seborrheic  keratosis75550.525-401Off4.4
Age Spot  Café Au Lait7555335-5514.24.4
Hybrid Light Brown Spots106435501–4.4
7555501
Mole75523150-18014.85.0
755310120-15014.85.0
Melasma7551031614.24.4
PIH7557107.814.24.4
Mole •2-3pulses •Endpoints : pigment removal, and mild erythema and edema • • Melasma and PIH •1-2 passes •Endpoints : slight darkening of pigment, and mild erythema and edema ※  Refer to the next page for other pigmented lesions.

Vascular Lesion Treatment

Vascular Lesion Treatment
LesionWavelength  (nm)Spot Size  (mm)Pulse  Duration  (ms)Fluence  (J/cm2)Frequency  (Hz)SCS
PrePost
Telangiectasia106435180-20014.44.4
1064310180-20014.44.4
Venulectasia1064320160-18014.44.4
Reticular Vein1064330160-18014.44.4
Dark Circles  under eyes106453015014.44.4
Port Wine Stains106453080-10014.44.4
•Telangiectasia : mainly on the face and the nose, red and less then 1mm in diameter •Venulectasia : mainly on the face or/and legs, dark red and 1-2mm in diameter •Reticular Vein : mainly on legs, blue and more than 2mn in diameter • • Dark circles and Port Wine Stains •Apply anesthetic cream for 20-30minutes •Endpoints : purpura(may be delayed), and erythema and edema •Time interval for treatments : 6-8weeks ※  Refer to the next page for other vascular lesions.

Skin Rejuvenation

Skin Rejuvenation
LesionsMode  (nm)Spot Size  (mm)Pulse  Width  (ms)Fluence  (J/cm2)HzSCS
PrePost
Alex Toning75570.25-88-10OffOff
755100.34-78-10OffOff
Genesis106470.388-10OffOff
1064100.358-10OffOff
Core Heating1064153092OffOff
Dermal Remodeling10641530 – 5025 – 3024.44.4
Onychomycosis10645, 70.55-72OffOff
106472015-202OffOff
Wart1064520-50180-25025.05.0
Onychomycosis and Wart •1-3passes on treatment area •Endpoints : slight ash gray coloration that occurs immediately after laser irradiation or may be subtle •Number of sessions : 3-5sessions, every 4weeks •Do not place the tip of the handpiece in contact with the skin when lasing the wart •Hold the tip of the handpiece 1cm away from the lesion •Wipe the cartridge with alcohol swap after each treatment ※ Refer to the next page for skin rejuvenation procedures.

 BEFORE & AFTER

 Vascular Lesions

Acne

Hair Removal

Skin Rejuvenation

Hair Removal

Picocare Majesty

250 PICOSECOND ND:YAG LASER

System TypeNd:YAG
Wavelength
1064nm, 532nm
Output
500mJ(1064nm), 250mJ(532nm)
Pulse Duration
250ps
Peak Power
1064nm : 2GW (@500Mj/250ps)
532nm : 1.3GW (@250Mj/190ps)
Spot Size
2mm ~ 10mm (step 1mm)
Repetition Rate
Single, 1~10 Hz
Handpiece
Zoom H/P
Collimation H/P
MLA H/P
DOE (532nm, 1064nm) H/P
DYE (595nm, 660nm), H/P

PROCEDURE

The shorter the pulse duration, the higher the peak power and the stronger the photoacoustic effect. If the photoacoustic effect is strong, only the target of the lesion can be broken into small pieces without damaging the surrounding tissues. 250 picosecond is a strong photoacoustic effect, and it can be safely and effectively treated by breaking down only the pigment and tattoo particles of the lesion.

Possibility of 250 Ps

PICOANDY Premium Specifications

Pulse Duration is 45% shorter.
Peak Power is 50% stronger than PICOANDY.

Effective LIOB Formation

Effective treatment for scar and skin rejuvenation via LIOB formation with shorter pulse duration and higher peak power.

Effective Tattoo Ink Removal

Shorter pulse duration with higher peak power makes it possible for the tattoo ink particles to be destroyed into smaller pieces, resulting in an effective tattoo removal.

Destruction of Melanosome in a safe way

Compared to 300 ps, which is SRT of 1 μm melanosome, 250 picosecond pulse duration is safer and more effective in treating melanosome without damaging surrounding tissues.

Handpiece

MLA Handpiece

  • Split one beam into multiple beams and output them in focus.
  • LIOB formation with high peak power
  • Effective in treating acne scars and pores

DOE Handpiece

  • Uniformly output one beam to multiple beams
  • Mild treatment is possible compared to MLA
  • Effective in treating pigmentation such as freckles

Indications

Scar TreatmentSkin RejuvenationEpidermal Benign Pigmented LesionsDermal Benign Pigmented LesionsVarious Color Tattoo
– Atrophic Scars– Uneven Skin Tone– Freckles– ABNOM– Black
– Hypertrophic Scars– Dull Skin Texture– Café-au-lait– Ota nevus– Blue
– Acne Scars– Large Pores– Lentigines– Ito Ota Blue– Red
– Fine Wrinkles– Age spot– Melasma

SKIN TYPE

By combining 7 types of handpieces and 4 wavelength

Pigmented Lesion Treatment

Lentigines

532nm, 6mm, 0.5 J/㎠, 3Hz, 1session

532nm, 6mm, 0.5 J/㎠, 4Hz, 1session

532nm, 6mm, 0.4 J/㎠, 6Hz, 1session

1st : 532nm, 5mm, 0.4 J/㎠, 5Hz,

2nd : 532nm, 10mm, 0.3 J/㎠, 10Hz

PIH post CO2 Fractional

MLA: 1064nm, 4mm, 0.8 J/㎠, 2Hz, 2session 6weeks apart

Pigmentation

Pigmentation

Melasma

Melasma

Epidermal Pigment & Uneven Skin Tone

Zoom, 1064nm, 8mm, 0.35J/㎠, 10Hz, 2 passes,

Zoom, 1064nm, 6mm, 0.3-0.4J/㎠, 10Hz, 2passes

Zoom, 1064nm, 4mm, 0.4J/㎠, 1pass

Zoom, 1064nm, 4mm, 0.25-0.3J/㎠, 1Hz, 1pass

Skin Rejuvenation & Scar

Large Pore & Scar

MLA, 1064nm, 4mm, 3.5 J/㎠, 7Hz

1st : MLA, 1064nm, 3mm, 6.0J/㎠, 5Hz,

2nd : MLA, 1064nm, 6mm, 1.5 J/㎠, 6Hz 3session of majesty + injection AH sub dermal

3rd : MLA, 1064nm, 5mm 2.5 J/㎠, 8Hz,

CLINICAL DATA

Large pores

Melasma

Pigmented lesion

V Laser

V Laser

LONG-PULSED 532NM KTP & 1064NM ND:YAG LASER

For Vascular Lesions, Benign Pigmentations & Skin Rejuvenation

Long-Pulsed

532nm KTP & 1064nm Nd:YAG Laser

  • Wide range of spot size, pulse duration, fluence, frequency
  • Adjustable contact cooling  temperature
  • One device for treatment of  various indications
  • High performance and safety
  • Easy and intuitive

ProductV-laser
Irradiation typeLong-Pulsed 532nm KTP & 1064nm Nd:YAG
Spot Size2,3,4,5,6,8,10,12mm
Cooling SystemSapphire Window Contact Cooling
Wavelength532nm1064nmGenesis
Max. Energy10J50J4J
Pulse Duration1~40ms5~60ms0.3ms
Repetition RateUp to 3HzUp to 5HzUp to 10Hz

LONG-PULSED 532NM KTP & 1064NM ND:YAG LASER

  • Long pulsed 532nm KTP for epidermal vascular or pigmented lesions such as rosacea, port wine strains or lentigines. (Skin rejuvenation,
  • Long pulsed 1064nm Nd:YAG for leg veins or pigmented lesions. (Skin rejuvenation, genesis collagen remodeling)
  • 300 microseconds of 1064nm bulk heating delivers to stimulate fibroblasts and neocollagenesis for improvement in uneven skin tone, dull skin texture, large pores, and fine wrinkles, diffuses redness and scars.
  • A wide range of pulse duration upto 40ms @ 532nm and 60nm @ 1064nm
  • Various spot sizes available from 2mm to 12mm
  • 4-step contact cooling system : 5, 10, 15, 20 degree Celsius.
  • Sapphire window contact cooling.

PROCEDURE

Irradiation Type
Long Pulsed Nd:YAG
Wavelength
532nm, 1064nm
Pulse duration
532nm : 1 to 40ms
1064nm : 5 to 60ms 
Genesis Mode : 0.3ms
Max Energy
532nm : 10J
1064nm : 50J
Genesis Mode : 4J
Repetition Rate
532nm : 0.5 to 3Hz 1064nm : 0.5 to 5Hz Genesis Mode : 0.5 to 10Hz
Spot size
2, 3, 4, 5, 6, 8, 10 ,12mm
Cooling
Sapphire Glass Contact Cooling
Dimensions
420(W)X793.2(D)X912.5(H)mm
Weight
80kg